DSpace@nitr >
National Institue of Technology- Rourkela >
Journal Articles >

Please use this identifier to cite or link to this item: http://hdl.handle.net/2080/241

Full metadata record

DC FieldValueLanguage
contributor.authorSahoo, P K-
contributor.authorSarangi, S K-
date.accessioned2006-02-23T09:13:34Z-
date.available2006-02-23T09:13:34Z-
date.issued1996-
identifier.citationCryogenics, Vol 36, Iss 5, P 343-349en
identifier.urihttp://hdl.handle.net/2080/241-
descriptionCopyright for this article belongs to Elsevier Science Ltd http://dx.doi.org/10.1016/0011-2275(96)81104-0en
description.abstractThe torque tubes of a superconducting generator belong to a unique class of heat exchangers where a single fluid stream (boil off helium vapour) exchanges heat with a metallic wall conducting heat from the ambient to the cold (liquid helium) space. The rate of heat leak to the cold space is the chief indicator of the performance of the exchanger. This rate of heat inleak has been found to be a function of two dimensionless parameters: a generalized cooling parameter Λ* and a temperature range parameter Ψ. A generalized design chart is presented which expresses the dimensionless heat flow rate Qc in terms of the parameters Λ* and Ψ. This chart will be useful for the design of torque tubes and vapour-cooled support members in cryogenic systemsen
format.extent777821 bytes-
format.mimetypeapplication/pdf-
language.isoen-
publisherElsevieren
subjectsuperconducting generatoren
subjecttorque tubesen
subjectfield windingen
subjectthermal modellingen
titleA new technique for the analysis of torque tube heat exchangers of superconducting generatorsen
typeArticleen
Appears in Collections:Journal Articles

Files in This Item:

File Description SizeFormat
skso12.pdf759KbAdobe PDFView/Open

Show simple item record

All items in DSpace are protected by copyright, with all rights reserved.

 

Powered by DSpace Feedback