dc.date.issued2025-12-
dc.identifier.citation12th International and 52nd National Conference on Fluid Mechanics and Fluid Power (FMFP), Nirma University, Ahemdabad, 19-21 December 2025en_US
dc.identifier.urihttp://hdl.handle.net/2080/5478-
dc.descriptionCopyright belongs to the proceeding publisher.en_US
dc.description.abstractThis work develops a numerical model to investigate solar panel cooling using different air-cooled channel configurations by attaching inverted T-shaped fins on photovoltaic (PV) cell to improve thermal performance. The present analysis done taking silicon as PV cell and copper as fin material. A parametric study was carried out with a computational exercise in ANSYS Fluent R22 by varying dimensionless parameters like Reynolds number (4000-22000), and in fin spacing (FS) of 20 mm, 35 mm, 50 mm ,65 mm and 80 mm with constant baseplate thickness of 2 mm and fin height (e) of 30 mm. Considering various turbulence models, the RNG 𝑘 − 𝜀 model with enhanced wall treatment(EWT) was chosen for simulating the fluid flow equations (mass, momentum, and energy). The result showed that the Nusselt number (Nuf) with fin PV cell increases with rise of Reynolds number (Re), also found the optimum thermal performance index (TPI) of 1.73 at Re= 6000 at FS of 20 mm. These parameters were systematically optimized in steps to enhance the overall heat transfer process.en_US
dc.subjectPV cellen_US
dc.subjectFin spacingen_US
dc.subjectThermal performance indexen_US
dc.subjectT-shaped finen_US
dc.subjectANSYS Fluenten_US
dc.titleA Thermal Performance Evaluation of Photovoltaic Cell Using Inverted T-Shaped Finsen_US