Please use this identifier to cite or link to this item: http://hdl.handle.net/2080/5177
Full metadata record
DC FieldValueLanguage
dc.contributor.authorKumar, Mani Shankar-
dc.contributor.authorRai, Shekha-
dc.contributor.authorKumar, Raja Ram-
dc.date.accessioned2025-05-20T05:03:46Z-
dc.date.available2025-05-20T05:03:46Z-
dc.date.issued2025-05-
dc.identifier.citation7th International Conference on Energy, Power and Environment, NIT Meghalaya, 9-11 May 2025en_US
dc.identifier.urihttp://hdl.handle.net/2080/5177-
dc.descriptionCopyright belongs to the proceeding publisher.en_US
dc.description.abstractIn a modern power system, Phasor Measurement Units (PMU) are a key components for real-time monitoring and stability assessment. However, network congestion, communication failures, cyber-attacks and equipment malfunctions can introduce missing values and outliers, leading to anomalies that are captured at Phasor Data Concentrators (PDCs). Such anomalies can potentially degrade the performance of an estimator and consequently lead to power system stability issues. To address this issue, a newly introduced method integrating Graph Convolutional Networks (GCN) and Graph Imputation Networks (GIN) with TLS-ESPRIT has been developed. The reliability of this integrated approach is confirmed through Monte Carlo simulations performed on signals with different oscillation modes and noise levels. These simulations highlight that combining GCN for outlier detection, GIN for data imputation, and TLS-ESPRIT for mode estimation surpasses conventional methods, particularly in the presence of significant data anomalies. The combination of GCN and GIN, along with the TLS-ESPRIT algorithm, presents a robust approach to overcoming the challenges associated with nonlinear data in PMU measurements. This technique ensures accurate mode estimation, thereby improving system stability and sustainability. This approach has also been tested on two areas of data, real-time data collected from the Western Electricity Coordinating Council (WECC) and IEEE 39-bus system data simulated in a Real-Time Digital Simulator (RTDS).en_US
dc.subjectPMUen_US
dc.subjectBad Dataen_US
dc.subjectCN-GINen_US
dc.subjectTLS-ESPRITen_US
dc.subjectMode Estimationen_US
dc.titleIdentification of Oscillatory Modes from Degraded PMU Measurements Using an ML-Based GCN-GIN Schemeen_US
dc.typeArticleen_US
Appears in Collections:Conference Papers

Files in This Item:
File Description SizeFormat 
2025_ICEPE_MSKumar_Identification.pdf3.25 MBAdobe PDFView/Open    Request a copy


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.