Title: | Design Considerations of Signal Acquisition Circuit Development for Piezoelectric Pressure Sensor |
Authors: | Shaw, Ankit Kumari, Abhilasha Kumar, H Prem Sai Kar, Sougata Kumar Dutta, Aveek Kundu, Sudip |
Keywords: | Piezoelectric sensor signal acquisition charge amplifier, signal conditioning STM32 microcontrolle data acquisition. |
Issue Date: | Dec-2024 |
Citation: | 21st IEEE INDICON 2024, IIT Kharagpur, India, 19-21 December 2024 |
Abstract: | This paper presents a comprehensive study on the design, modeling, and validation of a signal acquisition system for piezoelectric (PZ) sensors. The article focuses on modeling piezoelectric device behavior, including the development of an electric equivalent circuit to represent sensor characteristics. A key component discussed is the design of a low-cost charge amplifier, which amplifies the small electrical charges generated by piezoelectric sensors. The paper details the design considerations and performance evaluation of the charge amplifier. Experimental results, along with simulation-based verification, validate the system’s efficacy, demonstrating consistent performance in capturing the PZ sensor’s output. The integration of an STM32 microcontroller enables data acquisition with high-speed ADCs, ensuring reliable signal storage, processing, and analysis. |
Description: | Copyright belongs to the proceeding publisher. |
URI: | http://hdl.handle.net/2080/4940 |
Appears in Collections: | Conference Papers |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
2024_INDICON_AShaw_Design.pdf | 2.59 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.