Please use this identifier to cite or link to this item:
http://hdl.handle.net/2080/4911
Title: | Strength and Design Thickness of Pavements Using Geopolymer-Stabilized Pond Ash as Subbase and Base Material |
Authors: | Varma, Datla Neeraj Dash, Amruta Singh, Suresh Prasad |
Keywords: | Pond ash Geopolymer stabilization Strength properties Subbase and base materials Pavement thickness |
Issue Date: | Dec-2024 |
Citation: | Indian Geotechnical Conference(IGC), MIT Chhatrapati Sambhajinagar, Maharashtra, 19-21 December 2024 |
Abstract: | Huge quantities of pond ash (PA) are left unutilized in ash ponds without any practical application due to its poor pozzolanic/cementitious properties. For effective utilization of PA as a subbase and base material in pavements, it has been treated with conventional stabilizers (cement/lime). However, environmental issues with conventional stabilizers raised the necessity of using alternative eco-friendly stabilizers. Hence, in this study, PA is stabilized with different mix ratios of geopolymer (3%, 6%, 9%, 12%, and 15%), and laboratory investigations are made to assess its mechanical and mineralogical properties. Based on the results, the suitability of stabilized PA as a cementitious subbase (CTSB) and cementitious bases (CTB) of flexible pavement is assessed. Thereafter, pavement design is carried out using IITPAVE software for higher traffic load conditions. The PA-additive mixes achieved lower optimum moisture content and higher maximum dry unit weight with the inclusion of additives. The stabilized PA achieved higher unconfined compressive strength (UCS) due to the formation of cementitious products such as sodium alumina silicate hydrate, sodium alumina silicate, calcium alumina silicate hydrate, and calcium silicate hydrate. As per IRC: 37 (2018), PA stabilized with 3% and 6% geopolymer contents satisfied the requirements of CTSB material of flexible pavement, while 9%, 12%, and 15% geopolymer contents satisfied the requirements of CTB material. The overall thickness of the pavement is significantly reduced by using stabilized PA as CTSB and CTB materials when compared to granular subbase and base material. Hence, this study recommends the use of geopolymer-stabilized PA for sustainable construction practices. |
Description: | Copyright belongs to the proceeding publisher. |
URI: | http://hdl.handle.net/2080/4911 |
Appears in Collections: | Conference Papers |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
2024_IGC_DNVerma_Strength.pdf | 487.59 kB | Adobe PDF | View/Open Request a copy |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.