Please use this identifier to cite or link to this item: http://hdl.handle.net/2080/6033
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSatapathy, Subhalaxmi-
dc.contributor.authorRai, Shekha-
dc.date.accessioned2026-11-25T04:55:23Z-
dc.date.available2026-11-25T04:55:23Z-
dc.date.issued2026-10-
dc.identifier.citation9th IEEE Flagship Region 8 International Energy Conference(IEEE ENERGYCON 2026) Paris, France, 27-29 October 2026en_US
dc.identifier.urihttp://hdl.handle.net/2080/6033-
dc.descriptionCopyright belongs to proceeding publisheren_US
dc.description.abstractThe Phasor Measurement Unit (PMU) serves as a key component in maintaining the power system stability and resilience by increasing grid observability and situational awareness in interconnected power systems with real time mon-itoring abilities. But, the data obtained from PMUs may get degraded because of the factors such as communication error, hardware faults and cybersecurity issues resulting in missing values, outliers and noises in the signal. This corrupted data poses a serious threat to the entire power system network. In order to deal with these problems, this work presents a machine-learning driven approach for data recovery that employs Graph Convolutional Network (GCN) and Generative Adversarial Net-work (GAN). The GCN is utilised to detect and remove outliers using the spatial dependencies between PMU measurements, whereas the GAN is used to recover missing data through extraction of spatial-temporal information of the signal by means of the deep learning approach utilizing convolutional neural layers. Unlike traditional methods that mainly concentrate on missing value imputation or outlier identification, the presented method successively deals with outlier detection and missing data imputation combinedly through GCN and GAN. Subsequently, the TLS ESPRIT module is used to determine the mode attributes necessary for power system stability assessment. The suggested technique is verified by applying on a synthetic signal consisting of inter-area mode, an actual PMU power signal from the Western Electricity Coordinating Council (WECC) along with a signal taken from the New-England 39-bus test system, which have been generated through the Real-Time Digital Simulator (RTDS). The suggested framework obtains Data Recovery Relative Error values of 0.1196%, 0.2743%, and 0.2760% for synthetic, WECC, and New England 39 bus test signals, respectively, along with preserving their respective oscillatory modes properties. The out-comes indicate the suggested scheme’s effectiveness in increasing PMU data quality, improving grid monitoring, and facilitating accurate modes determination to preserve the stability of modern power systems.en_US
dc.subjectWAMSen_US
dc.subjectPMUen_US
dc.subjectDegraded data recoveryen_US
dc.subjectGCN-GANen_US
dc.subjectModes Identificationen_US
dc.titleA GCN-GAN based Oscillatory Modes Estimation Framework for Power System Stability Assessment in the degraded PMU measured data scenarioen_US
dc.typeArticleen_US
Appears in Collections:Conference Papers

Files in This Item:
File Description SizeFormat 
2026_EnergyCON_SSatpathy_AGCN-GAN.pdf12.57 MBAdobe PDFView/Open    Request a copy


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.