Please use this identifier to cite or link to this item:
http://hdl.handle.net/2080/6032Full metadata record
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Meher, Jayadev | - |
| dc.contributor.author | Roy, Krishna | - |
| dc.contributor.author | Ghosh, Arnab | - |
| dc.date.accessioned | 2026-11-25T04:55:00Z | - |
| dc.date.available | 2026-11-25T04:55:00Z | - |
| dc.date.issued | 2026-10 | - |
| dc.identifier.citation | 9th IEEE Flagship Region 8 International Energy Conference(IEEE ENERGYCON 2026) Paris, France, 27-29 October 2026 | en_US |
| dc.identifier.uri | http://hdl.handle.net/2080/6032 | - |
| dc.description | Copyright belongs to proceeding publisher | en_US |
| dc.description.abstract | Bringing reliable power to rural farms with a hybrid PV–pico-hydro–wind–battery DC microgrid puts a heavy, flexible load irrigation pumping on a battery that is interfaced through a dual active bridge (DAB). The energy management system (EMS) typically determines each source's power, assuming the DAB ideally delivers the set-point. It does not: under single-phase-shift control, the DAB keeps zerovoltage switching (ZVS) only near voltage matching, so at light load, the EMS can push the battery into a hard-switching region where loss and EMI rise. We propose an EMS that respects this limit. The DAB's ZVS-feasible power splits into separate charging and discharging intervals with a hard-switching gap between them; we add a distance-to-set constraint, so the dispatch keeps the battery inside a valid interval. A finitecontrol-set MPC is the natural tool here because it tracks battery power through the phase shift while directly enforcing ZVS. The proposed system is simulated in MATLAB/Simulink and experimentally, and the detailed results are presented. | en_US |
| dc.subject | DC microgrid | en_US |
| dc.subject | dual active bridge (DAB) | en_US |
| dc.subject | energy management system (EMS) | en_US |
| dc.subject | model predictive control (MPC) | en_US |
| dc.subject | pico-hydro | en_US |
| dc.subject | renewable energy | en_US |
| dc.title | Predictive Energy Management of a Dual Active Bridge-Interfaced Multi-Source Agricultural DC Microgrid | en_US |
| dc.type | Article | en_US |
| Appears in Collections: | Conference Papers | |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| 2026_EnergyCON_JMeher_Predictive.pdf | 704.25 kB | Adobe PDF | View/Open Request a copy |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.