Please use this identifier to cite or link to this item:
http://hdl.handle.net/2080/1214
Title: | A Novel Control Strategy for 400 Hz Aircraft Power Supply Using Resonant DC Link Inverter |
Authors: | Pattanaik, Sushant Kumar Mahapatra, K K |
Keywords: | Aircraft System Current Initialization Scheme Soft-Switching Inverter RDCLI (Resonant DC Link Inverter) ZVS (Zero Voltage Switching) |
Issue Date: | 2008 |
Citation: | 2nd National Conference on Advances in Energy Conversion Technologies (AECT 2008), April 18-19, 2008 |
Abstract: | This paper presents the control aspects in designing an aircraft power supply. Power supply design is done using a soft-switched Resonant DC Link Inverter (RDCLI). A novel current initialization scheme is adopted to avoid zero crossing failures. Zero-hysteresis bang-bang control is used for current control within the inverter. The power supply is designed for 400 Hz load. The soft-switched inverter provides adequate current regulator bandwidth besides reducing switching losses. The proposed solution is validated through extensive simulation. |
URI: | http://hdl.handle.net/2080/1214 |
Appears in Collections: | Conference Papers |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.