Please use this identifier to cite or link to this item: http://hdl.handle.net/2080/1008
Full metadata record
DC FieldValueLanguage
dc.contributor.authorRoy, G K-
dc.date.accessioned2009-08-06T05:44:37Z-
dc.date.available2009-08-06T05:44:37Z-
dc.date.issued1989-
dc.identifier.citationChemical Engineering World , Vol 24 ,No.9,1989 p.67-68en
dc.identifier.urihttp://hdl.handle.net/2080/1008-
dc.description.abstractIn view of its favourable thermal properties and economic availability, water is being used as a versatile heat exchange medium in industrial practice. For calculation of tube side heat transfer coefficient, equations of Dittus-Boeltier and Colburn (jH- factor) are quite often used.For moderate pressures and temperatures, the Dittus-Boeltier equation has been simplified and given as under by McAdams.en
dc.format.extent138676 bytes-
dc.format.mimetypeapplication/pdf-
dc.language.isoen-
dc.titlePrdiction of Tube Side Heat Trnasfer Coefficient for Water by Nomographen
dc.typeArticleen
Appears in Collections:Journal Articles

Files in This Item:
File Description SizeFormat 
gkroy 65.pdf135.43 kBAdobe PDFView/Open